RF Hardware

Site Hardware
Specification sheets for RF Hardware products are available to download below.
 
You may JUMP down the page to products of particular interest by clicking these links...
Mounting Clamps
Antenna Mast Mounting Clamps
are now all listed here »
 
 
Download information for Standoff Brackets
STANDOFF BRACKETS
for mounting antennas to a Pole or Wall
are now all listed here »
Download information for Standoff Brackets
Download information for Standoff Brackets
 
Download Specs for phasing harness
PHASING HARNESSES
for Yagi and Dipole Stack Arrays
10% Bandwidth, -15 dB <1.5:1 VSWR
 
ORDER CODE
Type
Freq Range
Bandwidth
Connectors
Power
Specs
PDY22
2-Way Yagi
70-85 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
Download Specs for phasing harness
PDY32
2-Way Yagi
148-174 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDY42
2-Way Yagi
400-520 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDY52A
2-Way Yagi
85-100 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDY52B
2-Way Yagi
100-118 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDYA2
2-Way Yagi
Air 118-136 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDY62
2-Way Yagi
520-800 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
50 W
PDY82
2-Way Yagi
800-960 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
50 W
PDY24
4-Way Yagi
70-85 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDY34
4-Way Yagi
148-174 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDY44
4-Way Yagi
400-520 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDY54A
4-Way Yagi
85-100 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDY54B
4-Way Yagi
100-118 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDYA4
4-Way Yagi
Air 118-136 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDY64
4-Way Yagi
520-800 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
50 W
PDY84
4-Way Yagi
800-960 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
50 W
PDD22
2-Way Dipole
70-85 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
Download Specs for phasing harness
PDDA2
2-Way Dipole
Air 118-136 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDD32
2-Way Dipole
148-174 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
500 W
PDD42
2-Way Dipole
400-520 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
50 W
PDD62
2-Way Dipole
520-820 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
50 W
PDD82
2-Way Dipole
800-960 MHz
10%, <1.5:1
N-Male IN, 2 x N-Fem OUT
50 W
PDD24
4-Way Dipole
70-85 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDDA4
4-Way Dipole
Air 118-136 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDD34
4-Way Dipole
148-174 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
500 W
PDD44
4-Way Dipole
400-520 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
50 W
PDD64
4-Way Dipole
520-820 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
50 W
PDD84
4-Way Dipole
800-960 MHz
10%, <1.5:1
N-Male IN, 4 x N-Fem OUT
50 W
Power Dividers

POWER DIVIDERS for Stack Arrays
Connectors determine maximum power

2-Way, 3-Way, 4-Way
Single Stage 10% Bandwidth and
Two Stage 25% Bandwidth
Better than -26 dB Return Loss

2 YEAR WARRANTY for all Power Dividers
ORDER CODE
Type
Freq Range
Bandwidth
Connectors
Power
Download
PD-NN2
2-Way Single Stage
Specify
10%, -26 dB
N-Fem IN, 2 x N-Fem OUT
500 W
Download information for Power Dividers
PD-NN3
3-Way Single Stage
Specify
10%, -26 dB
N-Fem IN, 3 x N-Fem OUT
500 W
PD-NN4
4-Way Single Stage
Specify
10%, -26 dB
N-Fem IN, 4 x N-Fem OUT
500 W
PD2NN2
2-Way Two Stage
Specify
25%, -26 dB
N-Fem IN, 2 x N-Fem OUT
500 W
PD2NN3
3-Way Two Stage
Specify
25%, -26dB
N-Fem IN, 3 x N-Fem OUT
500 W
PD2NN4
4-Way Two Stage
Specify
25%, -26dB
N-Fem IN, 4 x N-Fem OUT
500 W
PD-716N2
2-Way Single Stage
Specify
10%, -26 dB
7/16" Fem IN, 2 x N-Fem OUT
1 kW
Download information for Power Dividers
PD-716N3
3-Way Single Stage
Specify
10%, -26 dB
7/16" Fem IN, 3 x N-Fem OUT
1.5 kW
PD-716N4
4-Way Single Stage
Specify
10%, -26 dB
7/16" Fem IN, 4 x N-Fem OUT
2 kW
PD2716N2
2-Way Two Stage
Specify
25%, -26 dB
7/16" Fem IN, 2 x N-Fem OUT
1 kW
PD2716N3
3-Way Two Stage
Specify
25%, -26 dB
7/16" Fem IN, 3 x N-Fem OUT
1.5 kW
PD2716N4
4-Way Two Stage
Specify
25%, -26 dB
7/16" Fem IN, 4 x N-Fem OUT
2 kW
PD-7167162
2-Way Single Stage
Specify
10%, -26 dB
7/16" Fem IN, 2 x 7/16" Fem OUT
2 kW
Download information for Power Dividers
PD-7167163
3-Way Single Stage
Specify
10%, -26 dB
7/16" Fem IN, 3 x 7/16" Fem OUT
2 kW
PD-7167164
4-Way Single Stage
Specify
10%, -26 dB
7/16" Fem IN, 3 x 7/16" Fem OUT
2 kW
PD27167162
2-Way Two Stage
Specify
25%, -26 dB
7/16" Fem IN, 2 x 7/16" Fem OUT
2 kW
PD27167162
3-Way Two Stage
Specify
25%, -26 dB
7/16" Fem IN, 3 x 7/16" Fem OUT
2 kW
PD27167162
4-Way Two Stage
Specify
25%, -26 dB
7/16" Fem IN, 3 x 7/16" Fem OUT
2 kW
PD-787162
2-Way Single Stage
Specify
10%, -26 dB
7/8" EIA IN, 2 x 7/16" Fem OUT
4 kW
Download information for Power Dividers
PD-787163
3-Way Single Stage
Specify
10%, -26 dB
7/8" EIA IN, 3 x 7/16" Fem OUT
5 kW
PD-787164
4-Way Single Stage
Specify
10%, -26 dB
7/8" EIA IN, 4 x 7/16" Fem OUT
5 kW
PD2787162
2-Way Two Stage
Specify
25%, -26 dB
7/8" EIA IN, 2 x 7/16" Fem OUT
4 kW
PD2787163
3-Way Two Stage
Specify
25%, -26 dB
7/8" EIA IN, 3 x 7/16" Fem OUT
5 kW
PD2787164
4-Way Two Stage
Specify
25%, -26 dB
7/8" EIA IN, 4 x 7/16" Fem OUT
5 kW
PD-78782
2-Way Single Stage
Specify
10%, -26 dB
7/8" EIA IN, 2 x 7/8" EIA OUT
5 kW
Download information for Power Dividers
PD-78784
4-Way Single Stage
Specify
10%, -26 dB
7/8" EIA IN, 4 x 7/8" EIA OUT
5 kW
PD278782
2-Way Single Stage
Specify
25%, -26 dB
7/8" EIA IN, 2 x 7/8" EIA OUT
5 kW
PD278784
4-Way Single Stage
Specify
25%, -26 dB
7/8" EIA IN, 4 x 7/8" EIA OUT
5 kW
Cable Sets
We assemble Branch Feeder Cable Sets to your exact requirements. Contact Us...
Download information for Hybrid Couplers

HYBRID COUPLERS
N-FEMALE CONNECTORS, 50 OHM
400-570 MHz at -22 dB, < 1.15:1 VSWR

Constructed from brass and aluminium, these Hybrid Couplers split the input signal between two output ports, or combine two signals while maintaining high isolation between them.

Download information for Hybrid Couplers
ORDER CODE
Description
Specs
HBC3
Hybrid Coupler, 400-570 MHz at <1.15:1 VSWR, 3 dB, 50 Ohm, 50/50 coupling ratio, N-Female connectors, brass and aluminium, 200 Watts, includes N-Male 5 Watt Dummy Load
Download information for Hybrid Couplers
HBC6
Hybrid Coupler, 400-570 MHz at <1.15:1 VSWR, 6 dB, 50 Ohm, 75/25 coupling ratio, N-Female connectors, brass and aluminium, 200 Watts, includes N-Male 5 Watt Dummy Load
Download Specs for Yagi Strut Kits
 
Download details for FLA2000 coaxial power surge protector
COAXIAL POWER SURGE PROTECTION
Download details for NOVARIS coaxial power surge protectors
In the event of a lightning strike, protecting your expensive transmitter from a potentially destructive power surge is obviously an important precaution.
A coaxial power surge protector installed in the cable line will give your transmission equipment the best chance of survival.
A ground earthing kit is vitally important as well.
ORDER CODE
Description
Specs
FLA2000
Coaxial Power Surge Protector, Flange Mount through wall up to 12 mm thick, N-Female to N-Female, 1000 Volt DC sparkover, working frequency up to 1.2 GHz
Download details for FLA2000 coaxial power surge protector
ORDER CODE
Description
Connectors
Sparkover
Power Rating
Max Freq
Specs
CN-MF-90-2
Novaris Coaxial Power Surge Protector
N-Male/N-Female
90 Volt DC
0-40 Watt
2 GHz
Download details for FLA2000 coaxial power surge protector
CN-MF-230-2
Novaris Coaxial Power Surge Protector
N-Male/N-Female
230 Volt DC
40-125 Watt
2 GHz
CN-MF-350-2
Novaris Coaxial Power Surge Protector
N-Male/N-Female
350 Volt DC
125-300 Watt
2 GHz
CN-MF-600-2
Novaris Coaxial Power Surge Protector
N-Male/N-Female
600 Volt DC
300-800 Watt
2 GHz
CN-MF-1000-2
Novaris Coaxial Power Surge Protector
N-Male/N-Female
10000 Volt DC
800-1000 Watt
2 GHz
CN-FF-90-2
Novaris Coaxial Power Surge Protector
N-Female/N-Female
90 Volt DC
0-40 Watt
2 GHz
CN-FF-230-2
Novaris Coaxial Power Surge Protector
N-Female/N-Female
230 Volt DC
40-125 Watt
2 GHz
CN-FF-350-2
Novaris Coaxial Power Surge Protector
N-Female/N-Female
350 Volt DC
125-300 Watt
2 GHz
CN-FF-600-2
Novaris Coaxial Power Surge Protector
N-Female/N-Female
600 Volt DC
300-800 Watt
2 GHz
CN-FF-1000-2
Novaris Coaxial Power Surge Protector
N-Female/N-Female
10000 Volt DC
800-1000 Watt
2 GHz
For Surge Protectors with a Mounting Bracket, add '-M' to the order code. For price and availability, Enquire.
In the 2 GHz range, these connectors are also available :
BNC, 7/16 DIN, F-Type, UHF and TNC - For price and availability, Enquire.
ORDER CODE
Description
Connectors
Sparkover
Power Rating
Max Freq
Specs
CN-MF-90-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Male/N-Female
90 Volt DC
0-40 Watt
3 GHz
Download details for FLA2000 coaxial power surge protector
CN-MF-230-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Male/N-Female
230 Volt DC
40-125 Watt
3 GHz
CN-MF-350-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Male/N-Female
350 Volt DC
125-300 Watt
3 GHz
CN-MF-600-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Male/N-Female
600 Volt DC
300-800 Watt
3 GHz
CN-MF-1000-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Male/N-Female
10000 Volt DC
800-1000 Watt
3 GHz
CN-FF-90-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Female/N-Female
90 Volt DC
0-40 Watt
3 GHz
CN-FF-230-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Female/N-Female
230 Volt DC
40-125 Watt
3 GHz
CN-FF-350-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Female/N-Female
350 Volt DC
125-300 Watt
3 GHz
CN-FF-600-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Female/N-Female
600 Volt DC
300-800 Watt
3 GHz
CN-FF-1000-3
Novaris Coaxial Power Surge Protector, Replaceable Gas Tube
N-Female/N-Female
10000 Volt DC
800-1000 Watt
3 GHz
For power higher than 1000 Watts, please Enquire.

GROUND EARTHING KITS

Ground Earthing Kits are an essential precaution to protect coaxial cable and valuable transmission equipment from destruction in the event of a lightning strike.

For the maximum protection possible, a lightning power surge protector is also recommended.

Download information for Ground Earthing Kits
ORDER CODE
Description
Download
GK7850
Ground Earthing Kit for 7/8" Flexible Cable
Download information for Ground Earthing Kits
GK1250
Ground Earthing Kit for 1/2" Flexible Cable
GK1250SF
Ground Earthing Kit for 1/2" Super Flexible Cable
7859
Ground Earthing Kit for RU400 Low Loss (LMR400) or RG213 Cable
Download information for Avair AV-1000 Power and SWR Meter

POWER and SWR METER

Download information for Avair AV-1000 Power and SWR Meter
The Avair Model AV-1000 Power and SWR Meter is for HF, VHF, UHF and 23 cm. This is an insertion type RF wattmeter and can be permanently fitted into a transmission system for continuous monitoring of station working conditions.
It has identical styling with other models in the range and has a large clear meter for easy measurement readings. The unit can be operated without external power, however the built-in lamp for illumination requires an external 13.8 volt DC power supply.
Average or PEP measurements can be accessed at the switch of a button. The AV-1000 is an ideal choice to replace two or three separate meters limited to different bands. Operating instructions are provided with the meter.
ORDER CODE
Description
Specs
AV1000
Avair Model AV-1000 Power and SWR Meter, 1.8-160 MHz, 430-450 MHz, 800-930 MHz, 1240-1300 MHz, 5 Watt, 20 Watt, 200 Watt and 400 Watt power ranges, average or PEP switchable measurements
Download information for Avair AV-1000 Power and SWR Meter
Download information for Dummy Loads

DUMMY LOADS
UP TO 3 GHz, N-MALE CONNECTOR, 50 OHM

The purpose of a Dummy Load (also known as a Termination Load) is to absorb RF energy and convert it into heat. The dummy load takes the place of an antenna during transmitter testing and adjustment. Other applications where dummy loads are used include hybrid couplers, isolators, circulators, system testing and calibration.

Download information for Dummy Loads
ORDER CODE
Description
Specs
8258
Dummy Load, up to 5 Watts power input and 3 GHz, 50 Ohm, N-Male connector
Download information for Dummy Loads
8259
Dummy Load, up to 25 Watts power input and 3 GHz, 50 Ohm, N-Male connector
8260
Dummy Load, up to 60 Watts power input and 3 GHz, 50 Ohm, N-Male connector
Download Specs for Guy Wire Insulators

GUY WIRE INSULATOR
is now listed here »

Prevent high voltage from a lightning strike from reaching the ground through guy wires

 
ORDER CODE
Description
Specs
8769
Guy Wire Insulator, Porcelain, 6 cm x 4 cm x 4 cm, for guy wire up to 7 mm diameter
Download Specs for Guy Wire Insulators
Download information for Cable Ties and Tape
Download information for Cable Ties and Tape
CABLE TIES and TAPE
are now all listed here »
Download information for Cable Ties and Tape
Download information for Cable Ties and Tape
 
WARNING SIGNS for RF Hazard Areas
are now all listed here »
RF Hazard Area Warning Sign
RF Hazard Area Warning Sign
RF Hazard Area Warning Sign
RF Hazard Area Warning Sign
 
Download Specs for CDMA Power Divider Racks (Omnification Units)
CDMA POWER DIVIDER RACKS
(Omnification Units)
ORDER CODE
Description
Frequency
VSWR
Connectors
Power
Construction
Specs
3WR PD-850
3-Way CDMA Power Divider Rack
800-900 MHz
<1.2:1
N-Female
50 W
Brass, Copper, Mild Steel, Grey Powder Coat finish
Download Specs for CDMA Power Divider Racks (Omnification Units)
2WR PD-850
2-Way CDMA Power Divider Rack
800-900 MHz
<1.2:1
N-Female
50 W
Brass, Copper, Mild Steel, Grey Powder Coat finish
DCI Frequency Filters distributed by ZCG Scalar

DCI FILTERS
Resolve your interference problems

Distributed in Australia
by ZCG Scalar

DCI Product
Description
Specs
Bandpass Filters
VHF and UHF bandpass filters from DCI are available in 4-, 6-, 8- or 10-poles, depending on the selectivity required. DCI filters are passive and can be used in both the TX and RX pass. They are DC-grounded on both inputs and outputs for additional lightning protection. The filters come standard with type "N" connectors, with other types of connectors being optional.
Download Specs
Low Pass Filters
Low pass filters are typically used on transmitter outputs to reduce harmonics and broadband noise, and on receiver inputs to reduce fundamental overload from higher frequency transmitters. DCI lowpass filters have extremely low loss (0.1 dB) with an estimated power handling capability of 2 KW.
Broadband Duplexers
DCI broadband duplexers have steeper skirt selectivity than most duplexers on the market and are used where 800 MHz trunking systems coexist with cellular systems. They provide excellent separation between services, reduce broadband transmitter noise and reduce desense.
Multiple-window Filters
Multiple window filters are used where multiple transmit and receive bands exist and there are multiple receivers and transmitters in each band.
Transmitter Combiners
DCI's strength in this market is the design and fabrication of custom devices where your needs are not met by off-the-shelf models. We will work with you to define your specifications and provide custom solutions at reasonable prices. We can provide you with the best balance of isolation and power loss for your application.
Tower-top Amplifiers
Tower-top amplifiers achieve excellent sensitivity by using very low noise (0.6 dB NF) LNA's while maintaining better-than-average intermod immunity through the use of very sharp, low-loss filtering.
Discrete-component Filters
Discrete component filters provide a wider variety of filter types and bandwidths than is attainable with cavities or helical resonators. They can be made in low pass, high pass, bandpass and bandstop versions at almost any frequency and passband width.
|
|
|
|
|
|
|
|
|